Introduction to Industrial Radiographic Testing
Radiographic Testing (RT) uses penetrating radiation — X-rays from an X-ray tube or gamma rays from a radioactive source — to produce an image of the internal structure of a weld or casting. Areas of different density and thickness absorb radiation differently, producing variations in image density on the radiographic film or digital detector.
RT is one of the two primary volumetric NDT methods (along with ultrasonic testing) accepted by ASME, API, and AWS codes for weld quality verification. It provides a permanent visual record of the internal weld condition and is particularly sensitive to volumetric defects such as porosity, slag inclusions, and incomplete penetration.
Radiation Sources Used in Industrial RT
The choice of radiation source depends on the material type, thickness, and required sensitivity:
- ◆X-ray machines (50–450 kV): Best image quality, adjustable energy, no radiation when switched off. Suitable for material thicknesses up to ~100 mm steel.
- ◆Iridium-192 (Ir-192): Most common industrial gamma source. Energy ~0.34 MeV. Suitable for 20–100 mm steel. Half-life 74 days.
- ◆Selenium-75 (Se-75): Energy ~0.2 MeV. Excellent for thin-wall austenitic stainless steel and small-bore pipework. Half-life 120 days.
- ◆Cobalt-60 (Co-60): High energy (1.25 MeV). Used for thick sections >100 mm. Half-life 5.27 years.
- ◆Ytterbium-169 (Yb-169): Low energy. Used for very thin sections and complex geometries.
Image Quality and Sensitivity
Radiographic image quality is verified using Image Quality Indicators (IQIs), also called penetrameters. Wire-type IQIs (as per ISO 19232-1) or hole-type IQIs (ASME Appendix A) are placed on the source side of the component. The thinnest visible wire or smallest visible hole diameter defines the radiographic sensitivity.
ASME Section V requires a minimum sensitivity of 2% of the material thickness for most pressure-containing welds — meaning a wire or hole equivalent to 2% of the thickness must be visible in the image.
Radiation Safety in Industrial RT
Industrial RT involves ionising radiation sources that must be handled in accordance with AEA Sri Lanka regulations and IAEA Safety Standards. All radiographers must hold a valid AEA radiographer licence. A controlled area must be established around the exposure location, and radiation levels must be monitored throughout.