MPI 6 min read

Magnetic Particle Inspection (MPI): A Practical Guide for Industrial Applications

Complete guide to Magnetic Particle Inspection (MPI) for surface and near-surface crack detection in ferromagnetic components. Methods, standards and Sri Lanka applications.

Principle of Magnetic Particle Inspection

Magnetic Particle Inspection (MPI) is a surface and near-surface NDT method applicable to ferromagnetic materials — primarily carbon steel, alloy steel, and cast iron. The component is magnetised, and fine iron particles (dry powder or wet fluorescent suspension) are applied to the surface. Defects that interrupt the magnetic field cause flux leakage, attracting the particles to form a visible indication.

MPI detects cracks, seams, laps, cold shuts, and other discontinuities that break or nearly break the surface. It is particularly sensitive to fatigue cracks and grinding cracks — the two most critical surface defect types in structural and rotating components.

Magnetisation Techniques

The choice of magnetisation technique depends on the component geometry and the expected defect orientation. Defects are most easily detected when they are perpendicular to the magnetic field direction.

  • ◆Yoke Magnetisation: A portable AC or DC electromagnet placed on the surface. Best for welds and flat surfaces.
  • ◆Prod Magnetisation: Current passed through the component via contact prods. Good for large plates and castings.
  • ◆Circular Magnetisation: Current passed through the component or a central conductor. Detects longitudinal defects in cylindrical parts.
  • ◆Coil Magnetisation: Component placed inside a coil. Detects transverse defects in elongated parts like shafts and bars.
  • ◆Multidirectional: Combines two or more magnetisation directions to detect defects of all orientations in a single operation.

Fluorescent vs Visible MPI

Standard MPI uses black or red particles visible under white light. Fluorescent MPI (also called UV-A or black light MPI) uses particles that fluoresce under ultraviolet-A light at 365 nm. Fluorescent MPI is 2–3 times more sensitive than visible MPI and is required for safety-critical applications such as aerospace components, lifting equipment certification, and nuclear components.

NDT Inspectors provides both visible and fluorescent MPI services, with UV-A lamps calibrated in accordance with ASTM E709 requirements.

Post-Inspection Demagnetisation

After MPI, ferromagnetic components often retain residual magnetism which can interfere with welding, machining, and compass-sensitive equipment. Demagnetisation is performed by passing the component through a decreasing AC field or by applying reversing DC fields. NDT Inspectors verifies residual field levels after demagnetisation using a calibrated Hall-effect gaussmeter.